HELPING THE OTHERS REALIZE THE ADVANTAGES OF DP50RB

Helping The others Realize The Advantages Of Dp50rb

Helping The others Realize The Advantages Of Dp50rb

Blog Article

The person is not allowed to open the handles and panel of the method, neither Observe: device disassemble is authorized. To ensure the method overall performance and basic safety, only Mindray engineers or engineers approved by Mindray can complete maintenance.

iZoom™ permits accurate viewing of picture from distance iWorks™ Protocol aids standardize workflow and reduce exam occasions

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Usually do not use any cables aside from the cables delivered Along with the device by Mindray. three. Utilize the cable provided with This method to attach the printer. Other cables might result in electric powered shock. Webpage 15: Mechanical Safety

Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.

5.two.three Geometric positioning accuracy Longitudinal geometric positioning accuracy  Test Step: Do changes as the way in which in tests the utmost depth. History the gap by 20mm Each individual section around the longitudinal targets line using the measurement caliper; Pick out the worth with the best error (to 20mm), determine the precision utilizing the components beneath The measurement caliper need to be positioned on the higher fringe of the concentrate on, Notice:... Web page 79 Transverse geometric Dp50rb login positioning accuracy  Test Move: Include the scan surface area from the phantom with drinking water or couple gel, gently Make contact with the probe With all the scan surface area Regulate the depth, creating the transverse targets for being displayed within the picture. Alter the focus issue for being posited beside the transverse targets (the common is just not obvious) Regulate parameters like get, TGC, generating Every transverse targets to generally be Evidently displayed. Website page eighty five.five.two.four Blackout Area Exam Stage: Cover the scan floor on the phantom with water or pair gel, Carefully Make contact with the probe Along with the scan surface Modify the depth at a lower worth, and established the main target at the closest place to the scan surface. Minimize the worth of parameters like AP, Obtain till the background noise just is usually found. Web page 81: Program Up grade And Routine maintenance

Maximum 4 instances tasking for a single transmitted beam, causing exceptional time resolution and higher frame price.

After changing the CPU module, crucial file must be produced Once more according to the new MAC handle and published into HDD of the device. Or else, the configuration operate of the product will likely be dropped. After getting rid of the CPU module, Take out panhead screws with washers (12 M3X6) set on the main device box, you will take from the board. Webpage 118 Determine eight-29 Disassemble the Control Panel Assembly (1) Hold the upper edge of control panel assembly, and open up the user interface. Determine 8-30 Disassemble the Control Panel Assembly (2) Right after eradicating one countersunk head self-tapping screw PT3X10 preset on the control panel and get out the plug of your keyboard and the principle device connecting cables, you could remove the user interface assembly.

Site 45 Return “Printer Service” webpage, Decide on the corresponding assistance in the printer checklist and improve the assistance. The procedure integrates motorists of HP printers, after HP printers are linked, motorists will likely be put in mechanically (about 10s).If car set up fails, icon will display on the correct lessen corner from the display screen to warn you that manual installation is critical. Website page 46: Network Preset

Get a complete and prolonged look at in the anatomical framework through panoramic imaging coupled with velocity indication and forward/backward scan skill creating scanning much simpler, smoother and more controllable.

Cut off cable ties connecting the primary device about the Screen by diagonal slicing pliers, and after that pull out the corresponding cable plugs.

Notice: Around the keep an eye on, the brightness adjustment will come in advance of contrast. Soon after readjusting the watch’s distinction and brightness, modify all preset and peripheral options.